Jump to: navigation, search

GVP MCP:mpc:cpa-fastbusy

(Created page with "---- __NOTOC__ <!-- ==================== --> <!-- DO NOT EDIT --> =Published= {{Optionstmp |internalformid=1 (DO NOT EDIT THIS VALUE) |fromxml=true |docstatus=Published...")
 
 
(15 intermediate revisions by 4 users not shown)
Line 1: Line 1:
----
+
{{PubOption
__NOTOC__
 
 
 
<!-- ==================== -->
 
<!-- DO NOT EDIT -->
 
=Published=
 
{{Optionstmp
 
|internalformid=1 (DO NOT EDIT THIS VALUE)
 
|fromxml=true
 
|docstatus=Published
 
|fromxml=true
 
|parameter=cpa.fastbusy
 
|urlparameter=cpa-fastbusy
 
|displayname=Fast busy pattern
 
 
|hidden=false
 
|hidden=false
 
|default=na_fastbusy
 
|default=na_fastbusy
 
|valid=
 
|valid=
 +
Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
 
|takeseffect=At start/restart
 
|takeseffect=At start/restart
|shortdesc=Specifies tones for CPA's fast busy pattern. Default tone value is builtin North American fast busy (NA fast busy). Value "Disable" disables fast busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.<br> The builtin North American fast busy has three segments. All segments are the same and are defined as follows:<br> <table border="1"> <tr> <td><B>Segment</B></td> <td><B>f1 min-max (Hz)</B></td> <td><B>f2 min-max (Hz)</B></td> <td><B>ontime min-max (ms)</B></td> <td><B>offtime min-max (ms)</B></td> </tr> <tr> <td>1</td> <td>460-500</td> <td>600-640</td> <td>160-320</td> <td>180-320</td> </tr> <tr> <td>2</td> <td>460-500</td> <td>600-640</td> <td>160-320</td> <td>180-320</td> </tr> <tr> <td>3</td> <td>460-500</td> <td>600-640</td> <td>160-320</td> <td>180-320</td> </tr> </table>
+
|shortdesc=
|section=mpc
+
 
|urlsection=mpc
+
Specifies tones for CPA's fast busy pattern. Default tone value
|groupid=grpMedia
+
is builtin North American fast busy (NA fast busy). Value "Disable"
|groupname=Media Processing
+
disables fast busy detection. Valid tones include builtins and
|format=chooseMultiple
+
Custom tone 1 to Custom tone 10.<br />
|prodshort=GVP
 
|component=GVP_MCP
 
|compshort=MediaControlPlatform
 
}}
 
[[Category:GVP_MCP_options]]
 
  
<!-- DO NOT EDIT -->
+
The builtin North American fast busy has three segments.
<!-- ==================== -->
+
All segments are the same and are defined as follows:<br />
 +
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
 +
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
 +
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
  
==Extended Description==
 
  
{{Extended
 
|internalformid=1 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|mandatory=
 
|introduced=
 
|modified=
 
|discontinued=
 
|feature=
 
|relatedoptions=
 
|relatedlinks=
 
|configobject=
 
|moredesc=
 
 
}}
 
}}
 +
{{DraftOption}}
  
=Draft=
+
{{PubExtended}}
  
{{Optionstmp
+
{{DraftExtended}}
|internalformid=2 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|parameter=
 
|displayname=
 
|hidden=
 
|default=
 
|valid=
 
|takeseffect=
 
|shortdesc=
 
|section=
 
|groupid=
 
|groupname=
 
|format=
 
|prodshort=
 
}}  
 
  
==Extended Description==
+
{{OptionCreate
 +
|component=GVP_MCP
 +
|compshort=GVP_MCP
 +
|prodshort=GVP
 +
|configobject=Application
 +
|section=mpc
 +
|parameter=cpa.fastbusy
 +
|groupid=grpMedia
 +
|groupname=Media Processing
 +
|format=chooseMultiple
 +
|displayname=Fast busy pattern
 +
}}
  
{{Extended
+
[[Category:GVP_MCP_options]]
|internalformid=2 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|mandatory=
 
|introduced=
 
|modified=
 
|discontinued=
 
|feature=
 
|relatedoptions=
 
|relatedlinks=
 
|configobject=
 
|moredesc=
 
}}
 

Latest revision as of 15:49, June 29, 2020



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.fastbusy

Default Value: na_fastbusy
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's fast busy pattern. Default tone value is builtin North American fast busy (NA fast busy). Value "Disable" disables fast busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American fast busy has three segments. All segments are the same and are defined as follows:
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)

Draft Option

No draft option

This page was last edited on June 29, 2020, at 15:49.