Jump to: navigation, search

GVP MCP:mpc:cpa-fastbusy

 
(6 intermediate revisions by 2 users not shown)
Line 5: Line 5:
 
Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
 
Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
 
|takeseffect=At start/restart
 
|takeseffect=At start/restart
|shortdesc=Specifies tones for CPA's fast busy pattern. Default tone value is builtin North American fast busy (NA fast busy). Value "Disable" disables fast busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.<br /> The builtin North American fast busy has three segments. All segments are the same and are defined as follows:<br /> Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br /> Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br /> Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
+
|shortdesc=
 +
 
 +
Specifies tones for CPA's fast busy pattern. Default tone value
 +
is builtin North American fast busy (NA fast busy). Value "Disable"
 +
disables fast busy detection. Valid tones include builtins and
 +
Custom tone 1 to Custom tone 10.<br />
 +
 
 +
The builtin North American fast busy has three segments.
 +
All segments are the same and are defined as follows:<br />
 +
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
 +
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
 +
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)<br />
 +
 
 +
 
 
}}
 
}}
 
{{DraftOption}}
 
{{DraftOption}}

Latest revision as of 15:49, June 29, 2020



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.fastbusy

Default Value: na_fastbusy
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's fast busy pattern. Default tone value is builtin North American fast busy (NA fast busy). Value "Disable" disables fast busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American fast busy has three segments. All segments are the same and are defined as follows:
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=160-320(ms), offtime=180-320(ms)