GVP MCP:mpc:cpa-sit vacantcircuit
(6 intermediate revisions by 2 users not shown) | |||
Line 5: | Line 5: | ||
Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none". | Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none". | ||
|takeseffect=At start/restart | |takeseffect=At start/restart | ||
− | |shortdesc=Specifies tones for CPA's SIT vacant circuit pattern. Default tone value is builtin North American SIT vacant circuit (NA SIT vacantcircuit). Value "Disable" disables SIT vacant circuit detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.<br /> The builtin North American sit vacant circuit has three segments. Each segment is defined as follows:<br /> Segment 1: f1=950-1020(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-60(ms)<br /> Segment 2: f1=1310-1430(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)<br /> Segment 3: f1=1740-1850(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-100(ms)<br /> | + | |shortdesc= |
+ | |||
+ | Specifies tones for CPA's SIT vacant circuit pattern. Default tone | ||
+ | value is builtin North American SIT vacant circuit | ||
+ | (NA SIT vacantcircuit). Value "Disable" disables SIT vacant circuit | ||
+ | detection. Valid tones include builtins and Custom tone 1 to | ||
+ | Custom tone 10.<br /> | ||
+ | |||
+ | The builtin North American sit vacant circuit has three segments. | ||
+ | Each segment is defined as follows:<br /> | ||
+ | Segment 1: f1=950-1020(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-60(ms)<br /> | ||
+ | Segment 2: f1=1310-1430(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)<br /> | ||
+ | Segment 3: f1=1740-1850(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-100(ms)<br /> | ||
+ | |||
+ | |||
+ | |||
}} | }} | ||
{{DraftOption}} | {{DraftOption}} |
Latest revision as of 15:49, June 29, 2020
View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
Draft Option
No draft option
This page was last edited on June 29, 2020, at 15:49.
Comments or questions about this documentation? Contact us for support!