Revision as of 20:35, March 29, 2019
View in ref guide.
Edit this option Publish this option Clear draft content
Published Option
referxferwaitbye
Default Value: 0
Valid Values: sip.referxferwaitbye should be a non-negative integer and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart
Wait for remote to disconnect after NOTIFY. This specifies a timeout value to wait for BYE message from the remote end before sending BYE to disconnect the call. If it is zero, it will send BYE right after a NOTIFY/200 is received. If it is non-zero, it will wait for the configured timeout (in milliseconds) before sending the BYE. Values are specified in millisecond.
Draft Option
No draft option