Jump to: navigation, search

GVP MCP:mpc:cpa-sit vacantcircuit

(No difference)

Revision as of 12:00, August 19, 2019



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.sit_vacantcircuit

Default Value: na_sit_vacantcircuit
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's SIT vacant circuit pattern. Default tone value is builtin North American SIT vacant circuit (NA SIT vacantcircuit). Value "Disable" disables SIT vacant circuit detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American sit vacant circuit has three segments. Each segment is defined as follows:
Segment 1: f1=950-1020(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-60(ms)
Segment 2: f1=1310-1430(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)
Segment 3: f1=1740-1850(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-100(ms)

Draft Option

No draft option

Comments or questions about this documentation? Contact us for support!