Jump to: navigation, search

GVP MCP:mpc:cpa-sit reorder

(No difference)

Revision as of 12:00, August 19, 2019



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.sit_reorder

Default Value: na_sit_reorder
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's SIT reorder pattern. Default tone value is builtin North American SIT reorder (NA SIT reorder). Value "Disable" disables SIT reorder detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American sit reorder has three segments. Each segment is defined as follows:
Segment 1: f1=874-955(Hz), f2=0-0(Hz), ontime=160-300(ms), offtime=0-60(ms)
Segment 2: f1=1400-1450(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-60(ms)
Segment 3: f1=1740-1850(Hz), f2=0-0(Hz), ontime=320-440(ms), offtime=0-100(ms)

Draft Option

No draft option

Comments or questions about this documentation? Contact us for support!