Jump to: navigation, search

GVP MCP:mpc:cpa-tone1-segment3-ontimemax

(Created page with "---- __NOTOC__ <!-- ==================== --> <!-- DO NOT EDIT --> =Published= {{Optionstmp |internalformid=1 (DO NOT EDIT THIS VALUE) |fromxml=true |docstatus=Published...")
 
m (1 revision imported)
(No difference)

Revision as of 19:47, January 11, 2016



Published

cpa.tone1.segment3.ontimemax

Default value: 20
Valid Values: A valid ontimemin must be a greater than or equal to 0 numeric
Changes Take Effect: At start/restart


Specifies maximum ontime of segment 3 of tone 1 (msec) for CPA. Setting the value to zero disables checking the ontime against a maximum value, so that any time greater than the minimum ontime will be matched.


Extended Description

Draft

Default value:
Valid Values:
Changes Take Effect:




Extended Description