Published

alarminterval

Default value: 900000
Valid Values: mpc.alarminterval must be an integer that is greater than or equal to 0 and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart


This parameter specifies the time interval to wait between sending failure alarm notifications. An initial alarm is generated on the first failure and if the failure continues we send another alarm notification with the updated failure count once the time interval specified by this parameter expires. The default value of this parameter is 15 minutes(900000 milli seconds), which means that we would send failure alarm notification for the first failure and then send another alarm notification after 15 minutes. This process is repeated until the root cause for the failure has been rectified.