Jump to: navigation, search

GVP MCP:log:compatible-output-priority

m (1 revision imported)
Line 1: Line 1:
----
+
{{PubOption
__NOTOC__
 
 
 
<!-- ==================== -->
 
<!-- DO NOT EDIT -->
 
=Published=
 
{{Optionstmp
 
|internalformid=1 (DO NOT EDIT THIS VALUE)
 
|fromxml=true
 
|docstatus=Published
 
|fromxml=true
 
|parameter=compatible-output-priority
 
|urlparameter=compatible-output-priority
 
|displayname=Enable 6.X compatible log output priority
 
|hidden=
 
 
|default=false
 
|default=false
 
|valid=<li><b>true</b> The log of the level specified by "Log Output Options" is sent to the specified output.
 
|valid=<li><b>true</b> The log of the level specified by "Log Output Options" is sent to the specified output.
Line 19: Line 5:
 
|takeseffect=Immediately
 
|takeseffect=Immediately
 
|shortdesc=Specifies whether the application uses 6.x output logic.
 
|shortdesc=Specifies whether the application uses 6.x output logic.
 +
}}
 +
{{DraftOption}}
 +
{{PubExtended}}
 +
{{DraftExtended}}
 +
{{OptionCreate
 +
|component=GVP_MCP
 +
|compshort=GVP_MCP
 +
|prodshort=GVP
 +
|configobject=Application
 
|section=log
 
|section=log
|urlsection=log
+
|parameter=compatible-output-priority
|groupid=grpLogging
 
|groupname=Logging
 
|format=boolean
 
|prodshort=GVP
 
|component=GVP_MCP
 
|compshort=MediaControlPlatform
 
}}
 
[[Category:GVP_MCP_options]]
 
 
 
<!-- DO NOT EDIT -->
 
<!-- ==================== -->
 
 
 
==Extended Description==
 
 
 
{{Extended
 
|internalformid=1 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|mandatory=
 
|introduced=
 
|modified=
 
|discontinued=
 
|feature=
 
|relatedoptions=
 
|relatedlinks=
 
|configobject=
 
|moredesc=
 
 
}}
 
}}
  
=Draft=
+
[[Category:GVP_MCP_options]]
 
 
{{Optionstmp
 
|internalformid=2 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|parameter=
 
|displayname=
 
|hidden=
 
|default=
 
|valid=
 
|takeseffect=
 
|shortdesc=
 
|section=
 
|groupid=
 
|groupname=
 
|format=
 
|prodshort=
 
}}
 
 
 
==Extended Description==
 
 
 
{{Extended
 
|internalformid=2 (DO NOT EDIT THIS VALUE)
 
|docstatus=
 
|mandatory=
 
|introduced=
 
|modified=
 
|discontinued=
 
|feature=
 
|relatedoptions=
 
|relatedlinks=
 
|configobject=
 
|moredesc=
 
}}
 

Revision as of 02:44, October 31, 2016


View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

compatible-output-priority

Default Value: false

Valid Values:
  • true The log of the level specified by "Log Output Options" is sent to the specified output.
  • false The log of the level specified by "Log Output Options" and higher levels is sent to the specified output.
    Changes Take Effect: Immediately
    Specifies whether the application uses 6.x output logic.

  • Draft Option

    No draft option

    Comments or questions about this documentation? Contact us for support!