Jump to: navigation, search

GVP MCP:mpc:cpa-busy

Line 4: Line 4:
 
|valid=
 
|valid=
 
|takeseffect=At start/restart
 
|takeseffect=At start/restart
|shortdesc=Specifies tones for CPA's busy pattern. Default tone value is builtin North American busy (NA busy). Value "Disable" disables busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.<br> The builtin North American busy has three segments. All segments are the same and are defined as follows:<br> <table border="1"> <tr> <td><B>Segment</B></td> <td><B>f1 min-max (Hz)</B></td> <td><B>f2 min-max (Hz)</B></td> <td><B>ontime min-max (ms)</B></td> <td><B>offtime min-max (ms)</B></td> </tr> <tr> <td>1</td> <td>460-500</td> <td>600-640</td> <td>360-640</td> <td>360-640</td> </tr> <tr> <td>2</td> <td>460-500</td> <td>600-640</td> <td>360-640</td> <td>360-640</td> </tr> <tr> <td>3</td> <td>460-500</td> <td>600-640</td> <td>360-640</td> <td>360-640</td> </tr> </table>
+
|shortdesc=Specifies tones for CPA's busy pattern. Default tone value is builtin North American busy (NA busy). Value "Disable" disables busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.<br /> The builtin North American busy has three segments. All segments are the same and are defined as follows:<br /> Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)<br /> Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)<br /> Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)<br />
 
}}
 
}}
 
{{DraftOption}}
 
{{DraftOption}}
 +
 
{{PubExtended}}
 
{{PubExtended}}
 
{{DraftExtended}}
 
{{DraftExtended}}
 +
 
{{OptionCreate
 
{{OptionCreate
 
|component=GVP_MCP
 
|component=GVP_MCP

Revision as of 06:04, August 29, 2017



View in ref guide.

Edit this option          Publish this option          Clear draft content


Published Option

cpa.busy

Default Value: na_busy
Valid Values: Any combination of: "na_ringback", "na_busy", "na_fastbusy", "na_sit_nocircuit", "na_sit_vacantcircuit", "na_sit_operatorintercept", "na_sit_reorder", "standard_fax", "tone1", "tone2", "tone3", "tone4", "tone5", "tone6", "tone7", "tone8", "tone9" and "tone10". Or "none".
Changes Take Effect: At start/restart


Specifies tones for CPA's busy pattern. Default tone value is builtin North American busy (NA busy). Value "Disable" disables busy detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.

The builtin North American busy has three segments. All segments are the same and are defined as follows:
Segment 1: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)
Segment 2: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)
Segment 3: f1=460-500(Hz), f2=600-640(Hz), ontime=360-640(ms), offtime=360-640(ms)

Draft Option

No draft option