Revision as of 20:03, January 8, 2016 by WikiAPI (talk | contribs) (Created page with "---- __NOTOC__ <!-- ==================== --> <!-- DO NOT EDIT --> =Published= {{Optionstmp |internalformid=1 (DO NOT EDIT THIS VALUE) |fromxml=true |docstatus=Published...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

GVP MCP:mpc:cpa-sit reorder



Published

cpa.sit_reorder

Default value: na_sit_reorder
Valid Values:
Changes Take Effect: At start/restart


Specifies tones for CPA's SIT reorder pattern. Default tone value is builtin North American SIT reorder (NA SIT reorder). Value "Disable" disables SIT reorder detection. Valid tones include builtins and Custom tone 1 to Custom tone 10.
The builtin North American sit reorder has three segments. Each segment is defined as follows:
Segment f1 min-max (Hz) f2 min-max (Hz) ontime min-max (ms) offtime min-max (ms)
1 874-955 0-0 160-300 0-60
2 1400-1450 0-0 320-440 0-60
3 1740-1850 0-0 320-440 0-100


Extended Description

Draft

Default value:
Valid Values:
Changes Take Effect:




Extended Description