Default value: 15000
Valid Values: mpc.recordpostinterval must be an integer that is greater than or equal to 1
and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart
While doing MSML call recording the recordings are added to a list if they need to be posted to Amazon S3, Call Recording API, HTTP/HTTPS or SpeechMiner. A separate record posting thread wakes up from time to time and works on the list of records to be posted. This parameter specifies the time gap between consecutive processing attempts by this thread. The unit for this parameter is milliseconds and the default value is 15 seconds (15000 milliseconds).