GVP MCP:sip:call rate period
Published
- Link to option in reference manual (prodshort must be defined)
Extended Description
Draft
Extended Description
Comments or questions about this documentation? Contact us for support!
Default value: 0
Valid Values: sip.call_rate_period should be non-negative integer.
Changes Take Effect: At start/restart
Specify the call rate period in milliseconds for overload control. It works along with parameter call_rate. For example, if call_rate is set to 10 and call_rate_period is set to 500 (ms), then SIP line manager can accept at most 10 incoming calls every 500 milliseconds. If there are more than 10 incoming calls within 500 milliseconds, the excess calls will be rejected with response 486 Busy Here. By default, call_rate_period is set to 0, which means no overload control at all.
Default value:
Valid Values:
Changes Take Effect: