Revision as of 19:46, January 11, 2016 by Bgrenon (talk | contribs) (1 revision imported)
Jump to: navigation, search

GVP MCP:mpc:mediamgr-videofillingthreshold



Published

mediamgr.videofillingthreshold

Default value: 2000
Valid Values: mpc.mediamgr.videofillingthreshold must be a postive integer that is 0 or greater and less than or equal to the maximum integer as defined by the Genesys Administrator Help.
Changes Take Effect: At start/restart


This parameter is for video recording. It is used to decide when to trigger video filling; i.e., when the interval between the current and the last frame exceeds this threshold, video filling will be done on the next I-frame for this gap, with a new frame being created for each "videofillingframeduration". This parameter is in milliseconds, and this feature can be disabled by setting this to 0 or a large value.


Extended Description